The EAC91 combines a triode and a separate diode in a small envelope for UHF frequency conversion. In Mullard's circuit the triode acts as the local oscillator and the diode as the nonlinear mixing element: the received signal and the oscillation produce an intermediate frequency. The illustrated circuit is intended for signals up to 300 MHz and an intermediate-frequency output from 12 to 45 MHz. The two sections have separate electrodes, which explains their different connections in the circuit. The valve uses a seven-pin B7G miniature base and an indirectly heated 6.3 V, 300 mA heater, supplied by AC or DC according to Philips.

At a 200 V plate and −4 V triode grid, Philips gives typical values of 5.5 mA plate current, 2.5 mA/V transconductance, 12.4 kΩ internal resistance and amplification factor 31. Mullard instead publishes, still at 200 V but with the grid at −2.8 V, 7.5 mA, 2.8 mA/V, 12.8 kΩ and factor 36. The differing stated bias points account for at least part of the difference; the two groups of figures must not be mixed as one measurement. With external screening, Philips also specifies less than 0.1 pF capacitance between the triode grid and diode plate, relevant when the connections operate at high frequency.

Mullard’s circuit also separates the tuning of its elements: L2 has an adjustable core for the intermediate frequency, while L3 and L4 depend on signal frequency. Triode plate curves cover different biases; another family relates AC voltage to voltage obtained from the diode for different load resistors. Philips distinguishes 300 V plate at cutoff from 250 V in operation, specifies 50 V between heater and cathode and an external resistance between them up to 20 kΩ. It also distinguishes 5 mA average diode current from 50 mA peak. The drawing gives maximum diameter 19 mm and overall height 54 mm.

The sheets set triode operating limits of 250 V plate voltage, 2 W plate dissipation and 10 mA maximum cathode current; a 5 mA current limit is stated for the diode. Philips further distinguishes a 350 V peak inverse voltage for the diode. The 300 MHz figure is the specified frequency-converter operating limit, while 600 MHz is an oscillator limiting frequency: it does not specify converter operation at 600 MHz. The circuit, coils, screening and lead layout all contribute to RF performance. Sources: Philips ‘EAC91 Diode-Triode’ sheet, 6 June 1954; Mullard ‘EAC91 Miniature Diode Triode’, Issue 1.

Tube images

Pinout and connections

Base: Miniature 7-pin (B7G) (7 pin)

PinFunction
1a(d)
2k(d)
3h
4h
5k
6g1
7a

Electrical data

Heater

Heater voltage Vh
6.3 V

Datasheet PDF

EL84 ECC83 12AX7 EL34 6L6GC 300B KT88 GZ34

74,001 Valvole ricercabili sul sito
18,704 Datasheet PDF disponibili

How to use the Valve Archive

EnryLab Valve Archive allows you to search for PDF datasheets and technical documentation by entering the exact code of a vacuum tube. Enter codes such as EL84, ECC83, 12AX7, 6L6GC, or 300B to view variants, manufacturers, and documents available in the technical archive. The search uses exact matches, thus avoiding partial or irrelevant results and making it easier to find the correct datasheet.

Datasheet PDF and frequent searches

The most searched acronyms have dedicated and indexable pages, with clean URLs and linked documentation. You can start with frequent searches to quickly consult the most used valves in the audio, radio, and technical restoration fields.